Changes
On October 20, 2022 at 5:06:26 PM CDT, kelsey-friesenumanitoba-ca:
-
Changed title to Dawson Bay Li Taan Aen Staansyoon_54190 Sensors (previously Dawson Bay Li Taan Aen Staansyoon Sensors_54190)
f | 1 | { | f | 1 | { |
2 | "AlternateIdentifier": "300534061454190", | 2 | "AlternateIdentifier": "300534061454190", | ||
3 | "Description": "Made up of multiple components listed below. Serial | 3 | "Description": "Made up of multiple components listed below. Serial | ||
4 | number is Iridium Weather station IMEI\r\n\r\nEquipment cost: | 4 | number is Iridium Weather station IMEI\r\n\r\nEquipment cost: | ||
5 | $9,904.50 + Iridium satellite Premium Plan: $1,350\r\n\r\nSensor | 5 | $9,904.50 + Iridium satellite Premium Plan: $1,350\r\n\r\nSensor | ||
6 | details found in attachment - Instrument Details - HOBO MMF Weather | 6 | details found in attachment - Instrument Details - HOBO MMF Weather | ||
7 | Station 2", | 7 | Station 2", | ||
8 | "Notes": "HOBO brand field gear that includes various sensors | 8 | "Notes": "HOBO brand field gear that includes various sensors | ||
9 | attached to tripod outfitted with solar panel and battery located in | 9 | attached to tripod outfitted with solar panel and battery located in | ||
10 | housing box.\r\n\r\nThis meteorological station is located in Dawson | 10 | housing box.\r\n\r\nThis meteorological station is located in Dawson | ||
11 | Bay and is owned by the Manitoba Metic Federation | 11 | Bay and is owned by the Manitoba Metic Federation | ||
12 | (MMF).\r\n\r\nCalibration certificates stored in Lab Collector. They | 12 | (MMF).\r\n\r\nCalibration certificates stored in Lab Collector. They | ||
13 | can be provided upon request.", | 13 | can be provided upon request.", | ||
14 | "ResourceType": "Instrument", | 14 | "ResourceType": "Instrument", | ||
15 | "Subject": "METEOROLOGICAL STATIONS", | 15 | "Subject": "METEOROLOGICAL STATIONS", | ||
16 | "alternateIdentifierType": "Serial Number", | 16 | "alternateIdentifierType": "Serial Number", | ||
17 | "author": null, | 17 | "author": null, | ||
18 | "author_email": null, | 18 | "author_email": null, | ||
19 | "creator_user_id": "be605180-ed43-4028-a29f-31a3bcd40cd6", | 19 | "creator_user_id": "be605180-ed43-4028-a29f-31a3bcd40cd6", | ||
20 | "descriptionType": "TechnicalInfo", | 20 | "descriptionType": "TechnicalInfo", | ||
21 | "groups": [], | 21 | "groups": [], | ||
22 | "id": "8d7954d7-fa93-4bc3-910e-8fdc201c57cf", | 22 | "id": "8d7954d7-fa93-4bc3-910e-8fdc201c57cf", | ||
23 | "identifierType": "DOI", | 23 | "identifierType": "DOI", | ||
24 | "instrumentCreatorName": "Hoskin Scientific Limited", | 24 | "instrumentCreatorName": "Hoskin Scientific Limited", | ||
25 | "instrumentType": "Baseline", | 25 | "instrumentType": "Baseline", | ||
26 | "isopen": false, | 26 | "isopen": false, | ||
27 | "license_id": null, | 27 | "license_id": null, | ||
28 | "license_title": null, | 28 | "license_title": null, | ||
29 | "maintainer": null, | 29 | "maintainer": null, | ||
30 | "maintainer_email": null, | 30 | "maintainer_email": null, | ||
31 | "metadata_created": "2022-02-10T17:32:19.384057", | 31 | "metadata_created": "2022-02-10T17:32:19.384057", | ||
n | 32 | "metadata_modified": "2022-10-20T22:05:43.308301", | n | 32 | "metadata_modified": "2022-10-20T22:06:25.949644", |
33 | "modelNumber": "H22-E14, SOH118303", | 33 | "modelNumber": "H22-E14, SOH118303", | ||
34 | "name": "dawbay-met-sensors", | 34 | "name": "dawbay-met-sensors", | ||
35 | "nameType": "Organizational", | 35 | "nameType": "Organizational", | ||
36 | "notes": null, | 36 | "notes": null, | ||
37 | "num_resources": 0, | 37 | "num_resources": 0, | ||
38 | "num_tags": 0, | 38 | "num_tags": 0, | ||
39 | "organization": { | 39 | "organization": { | ||
40 | "approval_status": "approved", | 40 | "approval_status": "approved", | ||
41 | "created": "2021-11-13T11:44:31.164047", | 41 | "created": "2021-11-13T11:44:31.164047", | ||
42 | "description": "", | 42 | "description": "", | ||
43 | "id": "7d875a2d-6045-4066-9c38-d78542777be8", | 43 | "id": "7d875a2d-6045-4066-9c38-d78542777be8", | ||
44 | "image_url": "2021-11-13-004431.145535MMF-RRM-Logo.jpg", | 44 | "image_url": "2021-11-13-004431.145535MMF-RRM-Logo.jpg", | ||
45 | "is_organization": true, | 45 | "is_organization": true, | ||
46 | "name": "manitoba-metis-federation", | 46 | "name": "manitoba-metis-federation", | ||
47 | "state": "active", | 47 | "state": "active", | ||
48 | "title": "Manitoba M\u00e9tis Federation", | 48 | "title": "Manitoba M\u00e9tis Federation", | ||
49 | "type": "organization" | 49 | "type": "organization" | ||
50 | }, | 50 | }, | ||
51 | "owner_org": "7d875a2d-6045-4066-9c38-d78542777be8", | 51 | "owner_org": "7d875a2d-6045-4066-9c38-d78542777be8", | ||
52 | "private": false, | 52 | "private": false, | ||
53 | "related_campaigns": "[]", | 53 | "related_campaigns": "[]", | ||
54 | "related_datasets": "[\"5c2431c8-674f-4bb3-9f41-99f580316573\"]", | 54 | "related_datasets": "[\"5c2431c8-674f-4bb3-9f41-99f580316573\"]", | ||
55 | "related_platforms": "[\"3747ee00-6580-4b4f-adde-2c096a24d027\"]", | 55 | "related_platforms": "[\"3747ee00-6580-4b4f-adde-2c096a24d027\"]", | ||
56 | "relationships_as_object": [], | 56 | "relationships_as_object": [], | ||
57 | "relationships_as_subject": [], | 57 | "relationships_as_subject": [], | ||
58 | "resourceTypeGeneral": "Other", | 58 | "resourceTypeGeneral": "Other", | ||
59 | "resources": [], | 59 | "resources": [], | ||
60 | "schemeURI": | 60 | "schemeURI": | ||
61 | "http://vocab.nerc.ac.uk/collection/P19/current/PLSR0226/", | 61 | "http://vocab.nerc.ac.uk/collection/P19/current/PLSR0226/", | ||
62 | "sensorDetails": [ | 62 | "sensorDetails": [ | ||
63 | { | 63 | { | ||
64 | "instrumentSensorName": "Temperature and Relative Humidity", | 64 | "instrumentSensorName": "Temperature and Relative Humidity", | ||
65 | "instrumentSensorSerialNumber": "21048242", | 65 | "instrumentSensorSerialNumber": "21048242", | ||
66 | "lastCalibrationDate": "", | 66 | "lastCalibrationDate": "", | ||
67 | "sensorRange": "Temperature: -40\u00b0C to 75\u00b0C (-40\u00b0F | 67 | "sensorRange": "Temperature: -40\u00b0C to 75\u00b0C (-40\u00b0F | ||
68 | to 167\u00b0F); RH: 0-100% RH at -40\u00b0 to 75\u00b0C (-40\u00b0 to | 68 | to 167\u00b0F); RH: 0-100% RH at -40\u00b0 to 75\u00b0C (-40\u00b0 to | ||
69 | 167\u00b0F); exposure to conditions below -20\u00b0C (-4\u00b0F) or | 69 | 167\u00b0F); exposure to conditions below -20\u00b0C (-4\u00b0F) or | ||
70 | above 95% RH may temporarily increase the maximum RH sensor error by | 70 | above 95% RH may temporarily increase the maximum RH sensor error by | ||
71 | an additional 1%", | 71 | an additional 1%", | ||
72 | "sensorSensitivity": "Temperature: \u00b10.21\u00b0C from | 72 | "sensorSensitivity": "Temperature: \u00b10.21\u00b0C from | ||
73 | 0\u00b0 to 50\u00b0C (\u00b10.38\u00b0F from 32\u00b0 to 122\u00b0F); | 73 | 0\u00b0 to 50\u00b0C (\u00b10.38\u00b0F from 32\u00b0 to 122\u00b0F); | ||
74 | RH: \u00b12.5% from 10% to 90% RH typical to a maximum of \u00b13.5% | 74 | RH: \u00b12.5% from 10% to 90% RH typical to a maximum of \u00b13.5% | ||
75 | including hysteresis at 25\u00b0C (77\u00b0F); below 10% and above 90% | 75 | including hysteresis at 25\u00b0C (77\u00b0F); below 10% and above 90% | ||
76 | \u00b15% typical", | 76 | \u00b15% typical", | ||
77 | "sensorUnits": "\u00b0C and %" | 77 | "sensorUnits": "\u00b0C and %" | ||
78 | }, | 78 | }, | ||
79 | { | 79 | { | ||
80 | "instrumentSensorName": "Photosynthetically Active Radiation | 80 | "instrumentSensorName": "Photosynthetically Active Radiation | ||
81 | (PAR)", | 81 | (PAR)", | ||
82 | "instrumentSensorSerialNumber": "21040572", | 82 | "instrumentSensorSerialNumber": "21040572", | ||
83 | "lastCalibrationDate": "", | 83 | "lastCalibrationDate": "", | ||
84 | "sensorRange": "0 to 2500 \u03bcmol/m2/sec, wavelengths 400 to | 84 | "sensorRange": "0 to 2500 \u03bcmol/m2/sec, wavelengths 400 to | ||
85 | 700 nm", | 85 | 700 nm", | ||
86 | "sensorSensitivity": "\u00b15 \u03bcmol/m2/sec or \u00b1 5%, | 86 | "sensorSensitivity": "\u00b15 \u03bcmol/m2/sec or \u00b1 5%, | ||
87 | whichever is greater in sunlight; additional temperature induced error | 87 | whichever is greater in sunlight; additional temperature induced error | ||
88 | \u00b10.75 \u03bcmol/m2/sec/\u00b0C from 25\u00b0C (0.42 | 88 | \u00b10.75 \u03bcmol/m2/sec/\u00b0C from 25\u00b0C (0.42 | ||
89 | \u03bcmol/m2/sec/\u00b0F from 77\u00b0F)", | 89 | \u03bcmol/m2/sec/\u00b0F from 77\u00b0F)", | ||
90 | "sensorUnits": "\u03bcmol/m2/sec" | 90 | "sensorUnits": "\u03bcmol/m2/sec" | ||
91 | }, | 91 | }, | ||
92 | { | 92 | { | ||
93 | "instrumentSensorName": "Barometric Pressure", | 93 | "instrumentSensorName": "Barometric Pressure", | ||
94 | "instrumentSensorSerialNumber": "20812844", | 94 | "instrumentSensorSerialNumber": "20812844", | ||
95 | "lastCalibrationDate": "", | 95 | "lastCalibrationDate": "", | ||
96 | "sensorRange": "Rated for -40C to +70C, must be used inside | 96 | "sensorRange": "Rated for -40C to +70C, must be used inside | ||
97 | logger case, w/ 10 cm cable", | 97 | logger case, w/ 10 cm cable", | ||
98 | "sensorSensitivity": "\u00b13.0 mbar (0.088 in. Hg) over full | 98 | "sensorSensitivity": "\u00b13.0 mbar (0.088 in. Hg) over full | ||
99 | pressure range at 25\u00b0C (77\u00b0F); maximum error of \u00b15.0 | 99 | pressure range at 25\u00b0C (77\u00b0F); maximum error of \u00b15.0 | ||
100 | mbar (0.148 in. Hg) over -40\u00b0 to 70\u00b0C (-40\u00b0 to | 100 | mbar (0.148 in. Hg) over -40\u00b0 to 70\u00b0C (-40\u00b0 to | ||
101 | 158\u00b0F)", | 101 | 158\u00b0F)", | ||
102 | "sensorUnits": "mbar" | 102 | "sensorUnits": "mbar" | ||
103 | }, | 103 | }, | ||
104 | { | 104 | { | ||
105 | "instrumentSensorName": "Wind sensor/monitor", | 105 | "instrumentSensorName": "Wind sensor/monitor", | ||
106 | "instrumentSensorSerialNumber": "21055170", | 106 | "instrumentSensorSerialNumber": "21055170", | ||
107 | "lastCalibrationDate": "", | 107 | "lastCalibrationDate": "", | ||
108 | "sensorRange": "S-WCB-M003: 0 to 50 m/s (0 to 112 mph) ", | 108 | "sensorRange": "S-WCB-M003: 0 to 50 m/s (0 to 112 mph) ", | ||
109 | "sensorSensitivity": "0.20 m/s (0.46 mph) and 1.4 degrees", | 109 | "sensorSensitivity": "0.20 m/s (0.46 mph) and 1.4 degrees", | ||
110 | "sensorUnits": "m/s and degrees" | 110 | "sensorUnits": "m/s and degrees" | ||
111 | }, | 111 | }, | ||
112 | { | 112 | { | ||
113 | "instrumentSensorName": "Rain Gauge", | 113 | "instrumentSensorName": "Rain Gauge", | ||
114 | "instrumentSensorSerialNumber": "21050258", | 114 | "instrumentSensorSerialNumber": "21050258", | ||
115 | "lastCalibrationDate": "", | 115 | "lastCalibrationDate": "", | ||
116 | "sensorRange": "0 to 12.7 cm (0 to 5 in.) per hour, maximum 4000 | 116 | "sensorRange": "0 to 12.7 cm (0 to 5 in.) per hour, maximum 4000 | ||
117 | tips per logging interval", | 117 | tips per logging interval", | ||
118 | "sensorSensitivity": "0.01 in. (S-RGA-M002) or 0.2 mm | 118 | "sensorSensitivity": "0.01 in. (S-RGA-M002) or 0.2 mm | ||
119 | (S-RGB-M002)", | 119 | (S-RGB-M002)", | ||
120 | "sensorUnits": "mm" | 120 | "sensorUnits": "mm" | ||
121 | } | 121 | } | ||
122 | ], | 122 | ], | ||
123 | "state": "active", | 123 | "state": "active", | ||
124 | "tags": [], | 124 | "tags": [], | ||
t | 125 | "title": "Dawson Bay Li Taan Aen Staansyoon Sensors_54190", | t | 125 | "title": "Dawson Bay Li Taan Aen Staansyoon_54190 Sensors", |
126 | "titleType": "AlternativeTitle", | 126 | "titleType": "AlternativeTitle", | ||
127 | "type": "instrument_details", | 127 | "type": "instrument_details", | ||
128 | "url": null, | 128 | "url": null, | ||
129 | "valueURI": "SDN:P19::PLSR0226", | 129 | "valueURI": "SDN:P19::PLSR0226", | ||
130 | "version": null | 130 | "version": null | ||
131 | } | 131 | } |