Dictionnaire de données
Colonne Type Intitulé Description Units Media type Result Value Type Statistic Applied
Date_and_time timestamp Datetime

String corresponding to format 'YYYY-MM-DDThh:mm:ss.sssZ' or other valid ISO8601 string.

datetime atmosphere Actual None
air_pressure numeric Barometric Pressure

Measured using a barometer mounted inside the enclosure that houses the air temperature sensor. It is reported in millibars, where 1,000 millibars is the average air pressure at sea level. Changing pressure often indicates a coming change in the weather. Increasing pressure is associated with clearing skies. Decreasing pressure is associated with increasing cloudiness, and possibly an approaching storm.

millibar atmosphere Actual None
air_pressure_result_value_qualifier text Air pressure result value qualifier

A result value qualifier is a code field to identify measurements outside of the sensor calibrated detection range. "ADL" is a measurement above the detection limit and "BDL" is below the detection limit.

Additionally, field equipment error code "FEF" is given when the sensor or station is faulty and producing problematic data along with probably bad data code "prob_bad" when data is recognised as unusual during quality control that forms part of a feature that is probably inconsistent with real phenomena.

NA atmopshere Actual None
Photosynthetically_Active_Radiation numeric PAR

The intensity of the part of sunlight that plants can use to support new growth, and also the wavelengths of light that our eyes are sensitive to. It is measured on a small white disc that records the sum of light falling directly from the sun, and light scattered by the sky and clouds. It is reported in a unit called a micro-Einstein.

microEinstein atmosphere Actual None
Photosynthetically_Active_Radiation_result_value_qualifier text PAR result value qualifier

A result value qualifier is a code field to identify measurements outside of the sensor calibrated detection range. "ADL" is a measurement above the detection limit and "BDL" is below the detection limit.

Additionally, field equipment error code "FEF" is given when the sensor or station is faulty and producing problematic data along with probably bad data code "prob_bad" when data is recognised as unusual during quality control that forms part of a feature that is probably inconsistent with real phenomena.

NA atmosphere Actual None
air_temperature numeric Temperature

We report temperature in the shade, in Centigrade degrees. It is measured using an electronic thermometer shielded from direct sunlight, mounted inside an enclosure with louvered walls to allow free air flow past the sensor.

degrees celsius atmosphere Actual None
air_temperature_result_value_qualifier text Air temperature result value qualifier

A result value qualifier is a code field to identify measurements outside of the sensor calibrated detection range. "ADL" is a measurement above the detection limit and "BDL" is below the detection limit.

Additionally, field equipment error code "FEF" is given when the sensor or station is faulty and producing problematic data along with probably bad data code "prob_bad" when data is recognised as unusual during quality control that forms part of a feature that is probably inconsistent with real phenomena.

NA atmosphere Actual None
relative_humidity numeric RH

The amount of water vapour in the air reported as a percentage of the amount that would saturate it at the air temperature. Warmer air can hold more water vapour than cooler air.

percent atmosphere Actual None
relative_humidity_result_value_qualifier text Relative Humidity result value qualifier

A result value qualifier is a code field to identify measurements outside of the sensor calibrated detection range. "ADL" is a measurement above the detection limit and "BDL" is below the detection limit.

Additionally, field equipment error code "FEF" is given when the sensor or station is faulty and producing problematic data along with probably bad data code "prob_bad" when data is recognised as unusual during quality control that forms part of a feature that is probably inconsistent with real phenomena.

NA atmosphere Actual None
Precip text Rain

Reported in millimetres accumulated every 15 minutes in a gauge set about 1 m above the ground. Rain falling into a 6-inch diameter funnel drips onto a one of a pair of “buckets”, mounted on a teeter-totter. When one bucket is filled, the teeter-totter flips, the first bucket is emptied and rain then drips into the other “bucket” until it is filled, and so on. Each flip is equals 0.2 mm of rain.

millimeters atmosphere Actual None
Precip_result_value_qualifier text Precipitation result value qualifier

A result value qualifier is a code field to identify measurements outside of the sensor calibrated detection range. "ADL" is a measurement above the detection limit and "BDL" is below the detection limit.

Additionally, field equipment error code "FEF" is given when the sensor or station is faulty and producing problematic data along with probably bad data code "prob_bad" when data is recognised as unusual during quality control that forms part of a feature that is probably inconsistent with real phenomena.

NA atmosphere Actual None
wind_speed numeric Wind speed

Measured using a spinning anemometer mounted on the wind vane at the top of the tower, about 3 m above the ground. We report the average speed for every 15 minute period, in meters per second.

meters per second atmosphere Actual None
wind_speed_result_value_qualifier text Wind speed result value qualifier

A result value qualifier is a code field to identify measurements outside of the sensor calibrated detection range. "ADL" is a measurement above the detection limit and "BDL" is below the detection limit.

Additionally, field equipment error code "FEF" is given when the sensor or station is faulty and producing problematic data along with probably bad data code "prob_bad" when data is recognised as unusual during quality control that forms part of a feature that is probably inconsistent with real phenomena.

NA atmosphere Actual None
wind_speed_of_gust numeric Gust speed

The highest wind speed recorded in each 15 minute period, and are also recorded in meters per second, which can be converted into kilometres per hour.

meters per second atmosphere Actual None
wind_speed_of_gust_result_value_qualifier text Gust speed result value qualifier

A result value qualifier is a code field to identify measurements outside of the sensor calibrated detection range. "ADL" is a measurement above the detection limit and "BDL" is below the detection limit.

Additionally, field equipment error code "FEF" is given when the sensor or station is faulty and producing problematic data along with probably bad data code "prob_bad" when data is recognised as unusual during quality control that forms part of a feature that is probably inconsistent with real phenomena.

NA atmosphere Actual None
wind_from_direction numeric Wind direction

Measured using a wind vane mounted at the top of the tower. As we do with wind speed, we report the average direction for every 15 minutes, in compass degrees from true north.

degrees atmosphere Actual None
wind_from_direction_result_value_qualifier text Wind direction result value qualifier

A result value qualifier is a code field to identify measurements outside of the sensor calibrated detection range. "ADL" is a measurement above the detection limit and "BDL" is below the detection limit.

Additionally, field equipment error code "FEF" is given when the sensor or station is faulty and producing problematic data along with probably bad data code "prob_bad" when data is recognised as unusual during quality control that forms part of a feature that is probably inconsistent with real phenomena.

NA atmosphere Actual None
battery_output numeric Battery voltage

Power provided by an electric battery, in units of volts (V).

Note, name is standardized as 'battery output'.

volts atmosphere Actual None
battery_output_result_value_qualifier text Battery output result value qualifier

A result value qualifier is a code field to identify measurements outside of the sensor calibrated detection range. "ADL" is a measurement above the detection limit and "BDL" is below the detection limit.

Additionally, field equipment error code "FEF" is given when the sensor or station is faulty and producing problematic data along with probably bad data code "prob_bad" when data is recognised as unusual during quality control that forms part of a feature that is probably inconsistent with real phenomena.

NA atmosphere Actual None
Informations additionnelles
Field label
Study/Dataset Example
Format
CSV
Ckan url
https://canwin-datahub.ad.umanitoba.ca
Datastore active
True
Datastore contains all records of source file
True
Has views
True
Hash
b8fb560f6134e99c8dd131a309919514
Id
e4a3d32c-8b8e-4039-ada2-ee0ffc1bd8fb
Ignore hash
True
Mimetype
text/csv
Original url
https://canwin-datahub.ad.umanitoba.ca/data/dataset/5c2431c8-674f-4bb3-9f41-99f580316573/resource/e4a3d32c-8b8e-4039-ada2-ee0ffc1bd8fb/download/dawsonbay-54190_historical_2023-04-19.csv
Package id
5c2431c8-674f-4bb3-9f41-99f580316573
Position
7
Rescategory
data
Resource id
e4a3d32c-8b8e-4039-ada2-ee0ffc1bd8fb
Set url type
False
Size
2,6 mébi
State
active
Task created
2023-05-01 22:35:59.870147
Url type
upload