  <dc:description rdf:about="https://canwin-datahub.ad.umanitoba.ca/data/en/dataset/e3feba4e-a740-47ee-986c-9a103c450cf4">
    <dcat:Subject>Alec CT (conductivity, temperature) sampler</dcat:Subject>
    <dcat:AlternateIdentifier>1301</dcat:AlternateIdentifier>
    <dcat:alternateIdentifierType>Model Number</dcat:alternateIdentifierType>
    <dcat:modelNumber>1301</dcat:modelNumber>
    <dcat:instrumentType>Baseline</dcat:instrumentType>
    <dcat:Description>The COMPACT series instruments are small and highly accurate two-channel recorders using a micro-controller. Its 16bit A/D converter gives digital resolution of 1/65000 of the measuring range. Conductivity and Temperature sensors are located on these instruments.</dcat:Description>
    <dcat:instrumentCreatorName>JFE Advantech Co. Ltd.</dcat:instrumentCreatorName>
    <dcat:nameType>Organizational</dcat:nameType>
    <dcat:sensorDetails>
      <rdf:Description rdf:nodeID="N269176862844421fa1d8d5e167a984ca">
        <dcat:instrumentSensorName>Temperature Sensor</dcat:instrumentSensorName>
        <dcat:instrumentSensorSerialNumber>1301</dcat:instrumentSensorSerialNumber>
        <dcat:sensorRange>-5 - +40</dcat:sensorRange>
        <dcat:sensorUnits>Degrees Celsius</dcat:sensorUnits>
        <dcat:lastCalibrationDate>2015-12-01</dcat:lastCalibrationDate>
      </rdf:Description>
    </dcat:sensorDetails>
    <dcat:sensorDetails>
      <rdf:Description rdf:nodeID="N7f8df8e4788743debec2a12f3c69afc1">
        <dcat:instrumentSensorName>Conductivity Sensor</dcat:instrumentSensorName>
        <dcat:instrumentSensorSerialNumber>1301</dcat:instrumentSensorSerialNumber>
        <dcat:sensorRange>0-60</dcat:sensorRange>
        <dcat:sensorUnits>mS/cm</dcat:sensorUnits>
        <dcat:lastCalibrationDate>2015-12-01</dcat:lastCalibrationDate>
      </rdf:Description>
    </dcat:sensorDetails>
    <dcat:relation>
      <rdf:Description rdf:nodeID="N660e4e604e8e4d17bc55f96060268ddb">
        <dcat:entity_type>campaign</dcat:entity_type>
        <dcat:relation_type>related_to</dcat:relation_type>
        <dcat:title>MBGL Synoptic Survey 1 May-June 2016</dcat:title>
        <dcat:url>https://canwin-datahub.ad.umanitoba.ca/data/en/campaign/mbgl-ss1-may-june-2016</dcat:url>
      </rdf:Description>
    </dcat:relation>
    <dcat:distribution>
      <dcat:Distribution rdf:about="https://canwin-datahub.ad.umanitoba.ca/dataset/e3feba4e-a740-47ee-986c-9a103c450cf4/resource/8ac50809-7faa-4ef9-a469-4c5fbef9192e">
        <dct:title>ACT-HR Compact-CT 1301 Calibration Certification</dct:title>
        <dct:description>Calibration certificate for ACT-HR CT for December 1, 2015</dct:description>
        <dct:format>PDF</dct:format>
        <dcat:mediaType>application/pdf</dcat:mediaType>
        <dcat:accessURL rdf:resource="https://canwin-datahub.ad.umanitoba.ca/data/dataset/e3feba4e-a740-47ee-986c-9a103c450cf4/resource/8ac50809-7faa-4ef9-a469-4c5fbef9192e/download/calibcert_act-hr-sn1301-2015-12-16.pdf"/>
        <dcat:byteSize rdf:datatype="http://www.w3.org/2001/XMLSchema#decimal">62375.0</dcat:byteSize>