  <dc:description rdf:about="https://canwin-datahub.ad.umanitoba.ca/data/en/dataset/a10fe9aa-c17b-4d0e-ad5e-c76b8fb59e9e">
    <dcat:Subject>Alec CT (conductivity, temperature) sampler</dcat:Subject>
    <dcat:AlternateIdentifier>0247</dcat:AlternateIdentifier>
    <dcat:instrumentType>Baseline</dcat:instrumentType>
    <dcat:Description>Conductivity and Temperature logger</dcat:Description>
    <dcat:instrumentCreatorName>JFE Advantech Co., Ltd.</dcat:instrumentCreatorName>
    <dcat:nameType>Organizational</dcat:nameType>
    <dcat:Notes>Thermistor Resolution: 0.001°C; Thermistor Accuracy: ± 0.02 °C; Conductivity Resolution: 0.001 mS/cm; Conductiviy Accuracy: ± 0.02 mS/cm</dcat:Notes>
    <dcat:sensorDetails>
      <rdf:Description rdf:nodeID="N13adeabfb83a48dfac2f65f101662ab6">
        <dcat:instrumentSensorName>Thermistor</dcat:instrumentSensorName>
        <dcat:sensorRange>-5 ~ 40 °C</dcat:sensorRange>
        <dcat:sensorUnits>Celsius</dcat:sensorUnits>
        <dcat:lastCalibrationDate>2020-12-21</dcat:lastCalibrationDate>
      </rdf:Description>
    </dcat:sensorDetails>
    <dcat:sensorDetails>
      <rdf:Description rdf:nodeID="N164c142b748a4ab3a5aa3309a4bea434">
        <dcat:instrumentSensorName>EM Inductive Cell</dcat:instrumentSensorName>
        <dcat:instrumentSensorSerialNumber>0145</dcat:instrumentSensorSerialNumber>
        <dcat:sensorRange>0 ~ 60 mS/cm</dcat:sensorRange>
        <dcat:sensorUnits>mS/cm</dcat:sensorUnits>
        <dcat:lastCalibrationDate>2020-12-21</dcat:lastCalibrationDate>
      </rdf:Description>
    </dcat:sensorDetails>
    <dcat:distribution>
      <dcat:Distribution rdf:about="https://canwin-datahub.ad.umanitoba.ca/dataset/a10fe9aa-c17b-4d0e-ad5e-c76b8fb59e9e/resource/d0299244-8018-4f2c-9a42-8626c22e8efc">
        <dct:title>2020 Alec Infinity-CT 0247 Calibration Sheet</dct:title>
        <dct:description>Calibration sheet for Alec Infinity-CT 0247 for 2020</dct:description>
        <dct:format>PDF</dct:format>
        <dcat:mediaType>application/pdf</dcat:mediaType>
        <dcat:accessURL rdf:resource="https://canwin-datahub.ad.umanitoba.ca/data/dataset/a10fe9aa-c17b-4d0e-ad5e-c76b8fb59e9e/resource/d0299244-8018-4f2c-9a42-8626c22e8efc/download/a7ct2-usb-zf-247.pdf"/>
        <dcat:byteSize rdf:datatype="http://www.w3.org/2001/XMLSchema#decimal">1510581.0</dcat:byteSize>