{"help": "https://canwin-datahub.ad.umanitoba.ca/data/en/api/3/action/help_show?name=package_show", "success": true, "result": {"AlternateIdentifier": " 30023406813390", "Description": "Made up of multiple components listed below. Serial number is Iridium Weather station IMEI\r\n\r\nEquipment cost: $9,904.50 + Iridium satellite Premium Plan: $1,350\r\n\r\nSensor details found in attachment - Instrument Details - HOBO MMF Weather Station 1", "Notes": "HOBO brand field gear that includes various sensors attached to tripod outfitted with solar panel and battery located in housing box.\r\n\r\nThis meteorological station is located in St. Laurent and is owned by the Manitoba M\u00e9tis Federation (MMF).\r\n\r\nCalibration certificates stored in Lab Collector. They can be provided upon request.\r\n\r\nSite is currently decommissioned due to sensor and battery failure.\r\nArchived data collected prior to decommissioning will be made available.\r\nWhen active again, link to dataset page of station will be placed here.", "ResourceType": "Instrument", "Subject": "METEOROLOGICAL STATIONS", "alternateIdentifierType": "Serial Number", "author": null, "author_email": null, "creator_user_id": "c3ad971e-75e0-4e57-b825-8ed25f306937", "descriptionType": "TechnicalInfo", "id": "6bfb73f6-2b1f-48be-89a0-dbd977f78c8c", "identifierType": "DOI", "instrumentCreatorName": "Hoskin Scientific Limited", "instrumentType": "Baseline", "isopen": false, "license_id": null, "license_title": null, "maintainer": null, "maintainer_email": null, "metadata_created": "2021-11-24T20:34:19.910465", "metadata_modified": "2022-10-20T22:06:04.535640", "modelNumber": " H22-E14, SOH118303", "name": "decom-met-sensors", "nameType": "Organizational", "notes": null, "num_resources": 0, "num_tags": 0, "organization": {"id": "7d875a2d-6045-4066-9c38-d78542777be8", "name": "mmf", "title": "Manitoba M\u00e9tis Federation", "type": "organization", "description": "", "image_url": "2021-11-13-004431.145535MMF-RRM-Logo.jpg", "created": "2021-11-13T11:44:31.164047", "is_organization": true, "approval_status": "approved", "state": "active"}, "owner_org": "7d875a2d-6045-4066-9c38-d78542777be8", "private": false, "related_campaigns": [], "related_datasets": ["af55c1b1-9c24-4702-99e1-4339bde4b199"], "related_deployments": [], "related_platforms": ["83f1ea71-772b-4a6e-881c-a334bb35e549"], "resourceTypeGeneral": "Other", "schemeURI": "http://vocab.nerc.ac.uk/collection/P19/current/PLSR0226/", "state": "active", "title": "DECOMMISSIONED - St Laurent Li Taan Aen Staansyoon_13390  Sensors", "titleType": "AlternativeTitle", "type": "instrument_details", "url": null, "valueURI": "SDN:P19::PLSR0226", "version": null, "sensorDetails": [{"instrumentSensorName": "Temperature and Relative Humidity", "instrumentSensorSerialNumber": "21048243", "lastCalibrationDate": "", "sensorRange": "Temperature: -40\u00b0C to 75\u00b0C (-40\u00b0F to 167\u00b0F); RH: 0-100% RH at -40\u00b0 to 75\u00b0C (-40\u00b0 to 167\u00b0F); exposure to conditions below -20\u00b0C (-4\u00b0F) or above 95% RH may temporarily increase the maximum RH sensor error by an additional 1%", "sensorSensitivity": "Temperature: \u00b10.21\u00b0C from 0\u00b0 to 50\u00b0C (\u00b10.38\u00b0F from 32\u00b0 to 122\u00b0F); RH: \u00b12.5% from 10% to 90% RH typical to a maximum of \u00b13.5% including hysteresis at 25\u00b0C (77\u00b0F); below 10% and above 90% \u00b15% typical", "sensorUnits": "\u00b0C and %"}, {"instrumentSensorName": "Photosynthetically Active Radiation (PAR)", "instrumentSensorSerialNumber": "21040570", "lastCalibrationDate": "", "sensorRange": "0 to 2500 \u03bcmol/m2/sec, wavelengths 400 to 700 nm", "sensorSensitivity": "\u00b15 \u03bcmol/m2/sec or \u00b1 5%, whichever is greater in sunlight; additional temperature induced error \u00b10.75 \u03bcmol/m2/sec/\u00b0C from 25\u00b0C (0.42 \u03bcmol/m2/sec/\u00b0F from 77\u00b0F)", "sensorUnits": "\u03bcmol/m2/sec"}, {"instrumentSensorName": "Barometric Pressure", "instrumentSensorSerialNumber": " 20812842", "lastCalibrationDate": "", "sensorRange": "Rated for -40C to +70C, must be used inside logger case, w/ 10 cm cable", "sensorSensitivity": "\u00b13.0 mbar (0.088 in. Hg) over full pressure range at 25\u00b0C (77\u00b0F); maximum error of \u00b15.0 mbar (0.148 in. Hg) over -40\u00b0 to 70\u00b0C (-40\u00b0 to 158\u00b0F)", "sensorUnits": "mbar"}, {"instrumentSensorName": "Wind sensor/monitor", "instrumentSensorSerialNumber": "21055171", "lastCalibrationDate": "", "sensorRange": "S-WCB-M003: 0 to 50 m/s (0 to 112 mph) ", "sensorSensitivity": "0.20 m/s (0.46 mph) and 1.4 degrees", "sensorUnits": "m/s and degrees"}, {"instrumentSensorName": "Rain Gauge", "instrumentSensorSerialNumber": "21050257", "lastCalibrationDate": "", "sensorRange": "0 to 12.7 cm (0 to 5 in.) per hour, maximum 4000 tips per logging interval", "sensorSensitivity": "0.01 in. (S-RGA-M002) or 0.2 mm (S-RGB-M002)", "sensorUnits": "mm"}], "resources": [], "tags": [], "groups": [], "relationships_as_subject": [], "relationships_as_object": []}}