Metadata

Field Value
Data Collector Barber, David
Research Area Lake Waterhen
Field Value
Deployment ID GL_LWH_M_2021_05_10
Deployment Dates
Deployment Dates 1
Deployment start date
2021-05-10
Deployment end date
2021-09-02
Activity
Deployed at 1230pm, Retrieved, No PAR sensor installed
Notes
Location or Station ID GL_LWH_M
Field Value
Instrument Details
Instrument Details 1
Instrument Name
HOBO Oxygen Logger
Standardized Instrument Name
Instrument Unique ID
20775991
Instrument DOI
DOI
Description

Onset HOBO oxygen logger measures oxygen concentration with the HOBO U26 Dissolved Oxygen Data Logger. MBGL Instrument ID 219/EQ.

Instrument Details 2
Instrument Name
Alect CT 1589
Standardized Instrument Name
Alec CT (conductivity, temperature) sampler
Instrument Unique ID
1589
Instrument DOI
DOI
Description

ACT-HR Compact-CT Conductivity and Temperature sensor used on Manitoba Great Lakes Moorings. MBGL Instrument ID 10/EQ.

Instrument Details 3
Instrument Name
Ecotriplet 1442
Standardized Instrument Name
WETLabs ECO Triplet sensor
Instrument Unique ID
1442
Instrument DOI
DOI
Description

A three-optical-sensor, user-defined instrument that may carry any combination of single-wavelength fluorometers or scattering meters. The fluorometers can be configured (with typical sensitivities) for chlorophyll (470/695 nm, sensitivity 0.015-0.025 ug/l), FDOM (370/460 nm, sensitivity 0.184 ppb), phycocyanin (630/680 nm, 0.086 ppb), phycoerythrin (520/595 nm, sensitivity 0.086 ppb), uranine (470/530 nm, sensitivity 0.073 ppb) or rhodamine (520/595 nm, 0.086 ppb). The scattering meter can typically measure optical scattering at blue, green or red wavelengths (412, 470, 532, 650, 700 and 880 nm, sensitivity 0.002-0.003 m-1).

MBGL Instrument ID 4/EQ. UM ID 094364

Field Value
Related Files