Changes
On September 29, 2022 at 11:42:42 AM CDT, kelsey-friesenumanitoba-ca:
-
Changed value of field
Notes
toHOBO brand field gear that includes various sensors attached to tripod outfitted with solar panel and battery located in housing box. This meteorological station is located in St. Laurent and is owned by the Manitoba Métis Federation (MMF). Calibration certificates stored in Lab Collector. They can be provided upon request. Site is currently decommissioned due to sensor and battery failure. Archived data collected prior to decommissioning will be made available. When active again, link to dataset page of station will be placed here.
in DECOMMISSIONED - St Laurent Li Taan Aen Staansyoon Sensors
f | 1 | { | f | 1 | { |
2 | "AlternateIdentifier": " 30023406813390", | 2 | "AlternateIdentifier": " 30023406813390", | ||
3 | "Description": "Made up of multiple components listed below. Serial | 3 | "Description": "Made up of multiple components listed below. Serial | ||
4 | number is Iridium Weather station IMEI\r\n\r\nEquipment cost: | 4 | number is Iridium Weather station IMEI\r\n\r\nEquipment cost: | ||
5 | $9,904.50 + Iridium satellite Premium Plan: $1,350\r\n\r\nSensor | 5 | $9,904.50 + Iridium satellite Premium Plan: $1,350\r\n\r\nSensor | ||
6 | details found in attachment - Instrument Details - HOBO MMF Weather | 6 | details found in attachment - Instrument Details - HOBO MMF Weather | ||
7 | Station 1", | 7 | Station 1", | ||
8 | "Notes": "HOBO brand field gear that includes various sensors | 8 | "Notes": "HOBO brand field gear that includes various sensors | ||
9 | attached to tripod outfitted with solar panel and battery located in | 9 | attached to tripod outfitted with solar panel and battery located in | ||
10 | housing box.\r\n\r\nThis meteorological station is located in St. | 10 | housing box.\r\n\r\nThis meteorological station is located in St. | ||
11 | Laurent and is owned by the Manitoba M\u00e9tis Federation | 11 | Laurent and is owned by the Manitoba M\u00e9tis Federation | ||
12 | (MMF).\r\n\r\nCalibration certificates stored in Lab Collector. They | 12 | (MMF).\r\n\r\nCalibration certificates stored in Lab Collector. They | ||
n | 13 | can be provided upon request.", | n | 13 | can be provided upon request.\r\n\r\nSite is currently decommissioned |
14 | due to sensor and battery failure.\r\nArchived data collected prior to | ||||
15 | decommissioning will be made available.\r\nWhen active again, link to | ||||
16 | dataset page of station will be placed here.", | ||||
14 | "ResourceType": "Instrument", | 17 | "ResourceType": "Instrument", | ||
15 | "Subject": "METEOROLOGICAL STATIONS", | 18 | "Subject": "METEOROLOGICAL STATIONS", | ||
16 | "alternateIdentifierType": "Serial Number", | 19 | "alternateIdentifierType": "Serial Number", | ||
17 | "author": null, | 20 | "author": null, | ||
18 | "author_email": null, | 21 | "author_email": null, | ||
19 | "creator_user_id": "c3ad971e-75e0-4e57-b825-8ed25f306937", | 22 | "creator_user_id": "c3ad971e-75e0-4e57-b825-8ed25f306937", | ||
20 | "descriptionType": "TechnicalInfo", | 23 | "descriptionType": "TechnicalInfo", | ||
21 | "groups": [], | 24 | "groups": [], | ||
22 | "id": "6bfb73f6-2b1f-48be-89a0-dbd977f78c8c", | 25 | "id": "6bfb73f6-2b1f-48be-89a0-dbd977f78c8c", | ||
23 | "identifierType": "DOI", | 26 | "identifierType": "DOI", | ||
24 | "instrumentCreatorName": "Hoskin Scientific Limited", | 27 | "instrumentCreatorName": "Hoskin Scientific Limited", | ||
25 | "instrumentType": "Baseline", | 28 | "instrumentType": "Baseline", | ||
26 | "isopen": false, | 29 | "isopen": false, | ||
27 | "license_id": null, | 30 | "license_id": null, | ||
28 | "license_title": null, | 31 | "license_title": null, | ||
29 | "maintainer": null, | 32 | "maintainer": null, | ||
30 | "maintainer_email": null, | 33 | "maintainer_email": null, | ||
31 | "metadata_created": "2021-11-24T20:34:19.910465", | 34 | "metadata_created": "2021-11-24T20:34:19.910465", | ||
t | 32 | "metadata_modified": "2022-09-21T16:07:07.999521", | t | 35 | "metadata_modified": "2022-09-29T16:42:42.257937", |
33 | "modelNumber": " H22-E14, SOH118303", | 36 | "modelNumber": " H22-E14, SOH118303", | ||
34 | "name": "decom-met-sensors", | 37 | "name": "decom-met-sensors", | ||
35 | "nameType": "Organizational", | 38 | "nameType": "Organizational", | ||
36 | "notes": null, | 39 | "notes": null, | ||
37 | "num_resources": 0, | 40 | "num_resources": 0, | ||
38 | "num_tags": 0, | 41 | "num_tags": 0, | ||
39 | "organization": { | 42 | "organization": { | ||
40 | "approval_status": "approved", | 43 | "approval_status": "approved", | ||
41 | "created": "2021-11-13T11:44:31.164047", | 44 | "created": "2021-11-13T11:44:31.164047", | ||
42 | "description": "", | 45 | "description": "", | ||
43 | "id": "7d875a2d-6045-4066-9c38-d78542777be8", | 46 | "id": "7d875a2d-6045-4066-9c38-d78542777be8", | ||
44 | "image_url": "2021-11-13-004431.145535MMF-RRM-Logo.jpg", | 47 | "image_url": "2021-11-13-004431.145535MMF-RRM-Logo.jpg", | ||
45 | "is_organization": true, | 48 | "is_organization": true, | ||
46 | "name": "manitoba-metis-federation", | 49 | "name": "manitoba-metis-federation", | ||
47 | "state": "active", | 50 | "state": "active", | ||
48 | "title": "Manitoba M\u00e9tis Federation", | 51 | "title": "Manitoba M\u00e9tis Federation", | ||
49 | "type": "organization" | 52 | "type": "organization" | ||
50 | }, | 53 | }, | ||
51 | "owner_org": "7d875a2d-6045-4066-9c38-d78542777be8", | 54 | "owner_org": "7d875a2d-6045-4066-9c38-d78542777be8", | ||
52 | "private": false, | 55 | "private": false, | ||
53 | "related_campaigns": "[]", | 56 | "related_campaigns": "[]", | ||
54 | "related_datasets": "[\"d7e44314-bde4-4585-837c-6a48533688bb\"]", | 57 | "related_datasets": "[\"d7e44314-bde4-4585-837c-6a48533688bb\"]", | ||
55 | "related_platforms": "[\"83f1ea71-772b-4a6e-881c-a334bb35e549\"]", | 58 | "related_platforms": "[\"83f1ea71-772b-4a6e-881c-a334bb35e549\"]", | ||
56 | "relationships_as_object": [], | 59 | "relationships_as_object": [], | ||
57 | "relationships_as_subject": [], | 60 | "relationships_as_subject": [], | ||
58 | "resourceTypeGeneral": "Other", | 61 | "resourceTypeGeneral": "Other", | ||
59 | "resources": [], | 62 | "resources": [], | ||
60 | "schemeURI": | 63 | "schemeURI": | ||
61 | "http://vocab.nerc.ac.uk/collection/P19/current/PLSR0226/", | 64 | "http://vocab.nerc.ac.uk/collection/P19/current/PLSR0226/", | ||
62 | "sensorDetails": [ | 65 | "sensorDetails": [ | ||
63 | { | 66 | { | ||
64 | "instrumentSensorName": "Temperature and Relative Humidity", | 67 | "instrumentSensorName": "Temperature and Relative Humidity", | ||
65 | "instrumentSensorSerialNumber": "21048243", | 68 | "instrumentSensorSerialNumber": "21048243", | ||
66 | "lastCalibrationDate": "", | 69 | "lastCalibrationDate": "", | ||
67 | "sensorRange": "Temperature: -40\u00b0C to 75\u00b0C (-40\u00b0F | 70 | "sensorRange": "Temperature: -40\u00b0C to 75\u00b0C (-40\u00b0F | ||
68 | to 167\u00b0F); RH: 0-100% RH at -40\u00b0 to 75\u00b0C (-40\u00b0 to | 71 | to 167\u00b0F); RH: 0-100% RH at -40\u00b0 to 75\u00b0C (-40\u00b0 to | ||
69 | 167\u00b0F); exposure to conditions below -20\u00b0C (-4\u00b0F) or | 72 | 167\u00b0F); exposure to conditions below -20\u00b0C (-4\u00b0F) or | ||
70 | above 95% RH may temporarily increase the maximum RH sensor error by | 73 | above 95% RH may temporarily increase the maximum RH sensor error by | ||
71 | an additional 1%", | 74 | an additional 1%", | ||
72 | "sensorSensitivity": "Temperature: \u00b10.21\u00b0C from | 75 | "sensorSensitivity": "Temperature: \u00b10.21\u00b0C from | ||
73 | 0\u00b0 to 50\u00b0C (\u00b10.38\u00b0F from 32\u00b0 to 122\u00b0F); | 76 | 0\u00b0 to 50\u00b0C (\u00b10.38\u00b0F from 32\u00b0 to 122\u00b0F); | ||
74 | RH: \u00b12.5% from 10% to 90% RH typical to a maximum of \u00b13.5% | 77 | RH: \u00b12.5% from 10% to 90% RH typical to a maximum of \u00b13.5% | ||
75 | including hysteresis at 25\u00b0C (77\u00b0F); below 10% and above 90% | 78 | including hysteresis at 25\u00b0C (77\u00b0F); below 10% and above 90% | ||
76 | \u00b15% typical", | 79 | \u00b15% typical", | ||
77 | "sensorUnits": "\u00b0C and %" | 80 | "sensorUnits": "\u00b0C and %" | ||
78 | }, | 81 | }, | ||
79 | { | 82 | { | ||
80 | "instrumentSensorName": "Photosynthetically Active Radiation | 83 | "instrumentSensorName": "Photosynthetically Active Radiation | ||
81 | (PAR)", | 84 | (PAR)", | ||
82 | "instrumentSensorSerialNumber": "21040570", | 85 | "instrumentSensorSerialNumber": "21040570", | ||
83 | "lastCalibrationDate": "", | 86 | "lastCalibrationDate": "", | ||
84 | "sensorRange": "0 to 2500 \u03bcmol/m2/sec, wavelengths 400 to | 87 | "sensorRange": "0 to 2500 \u03bcmol/m2/sec, wavelengths 400 to | ||
85 | 700 nm", | 88 | 700 nm", | ||
86 | "sensorSensitivity": "\u00b15 \u03bcmol/m2/sec or \u00b1 5%, | 89 | "sensorSensitivity": "\u00b15 \u03bcmol/m2/sec or \u00b1 5%, | ||
87 | whichever is greater in sunlight; additional temperature induced error | 90 | whichever is greater in sunlight; additional temperature induced error | ||
88 | \u00b10.75 \u03bcmol/m2/sec/\u00b0C from 25\u00b0C (0.42 | 91 | \u00b10.75 \u03bcmol/m2/sec/\u00b0C from 25\u00b0C (0.42 | ||
89 | \u03bcmol/m2/sec/\u00b0F from 77\u00b0F)", | 92 | \u03bcmol/m2/sec/\u00b0F from 77\u00b0F)", | ||
90 | "sensorUnits": "\u03bcmol/m2/sec" | 93 | "sensorUnits": "\u03bcmol/m2/sec" | ||
91 | }, | 94 | }, | ||
92 | { | 95 | { | ||
93 | "instrumentSensorName": "Barometric Pressure", | 96 | "instrumentSensorName": "Barometric Pressure", | ||
94 | "instrumentSensorSerialNumber": " 20812842", | 97 | "instrumentSensorSerialNumber": " 20812842", | ||
95 | "lastCalibrationDate": "", | 98 | "lastCalibrationDate": "", | ||
96 | "sensorRange": "Rated for -40C to +70C, must be used inside | 99 | "sensorRange": "Rated for -40C to +70C, must be used inside | ||
97 | logger case, w/ 10 cm cable", | 100 | logger case, w/ 10 cm cable", | ||
98 | "sensorSensitivity": "\u00b13.0 mbar (0.088 in. Hg) over full | 101 | "sensorSensitivity": "\u00b13.0 mbar (0.088 in. Hg) over full | ||
99 | pressure range at 25\u00b0C (77\u00b0F); maximum error of \u00b15.0 | 102 | pressure range at 25\u00b0C (77\u00b0F); maximum error of \u00b15.0 | ||
100 | mbar (0.148 in. Hg) over -40\u00b0 to 70\u00b0C (-40\u00b0 to | 103 | mbar (0.148 in. Hg) over -40\u00b0 to 70\u00b0C (-40\u00b0 to | ||
101 | 158\u00b0F)", | 104 | 158\u00b0F)", | ||
102 | "sensorUnits": "mbar" | 105 | "sensorUnits": "mbar" | ||
103 | }, | 106 | }, | ||
104 | { | 107 | { | ||
105 | "instrumentSensorName": "Wind sensor/monitor", | 108 | "instrumentSensorName": "Wind sensor/monitor", | ||
106 | "instrumentSensorSerialNumber": "21055171", | 109 | "instrumentSensorSerialNumber": "21055171", | ||
107 | "lastCalibrationDate": "", | 110 | "lastCalibrationDate": "", | ||
108 | "sensorRange": "S-WCB-M003: 0 to 50 m/s (0 to 112 mph) ", | 111 | "sensorRange": "S-WCB-M003: 0 to 50 m/s (0 to 112 mph) ", | ||
109 | "sensorSensitivity": "0.20 m/s (0.46 mph) and 1.4 degrees", | 112 | "sensorSensitivity": "0.20 m/s (0.46 mph) and 1.4 degrees", | ||
110 | "sensorUnits": "m/s and degrees" | 113 | "sensorUnits": "m/s and degrees" | ||
111 | }, | 114 | }, | ||
112 | { | 115 | { | ||
113 | "instrumentSensorName": "Rain Gauge", | 116 | "instrumentSensorName": "Rain Gauge", | ||
114 | "instrumentSensorSerialNumber": "21050257", | 117 | "instrumentSensorSerialNumber": "21050257", | ||
115 | "lastCalibrationDate": "", | 118 | "lastCalibrationDate": "", | ||
116 | "sensorRange": "0 to 12.7 cm (0 to 5 in.) per hour, maximum 4000 | 119 | "sensorRange": "0 to 12.7 cm (0 to 5 in.) per hour, maximum 4000 | ||
117 | tips per logging interval", | 120 | tips per logging interval", | ||
118 | "sensorSensitivity": "0.01 in. (S-RGA-M002) or 0.2 mm | 121 | "sensorSensitivity": "0.01 in. (S-RGA-M002) or 0.2 mm | ||
119 | (S-RGB-M002)", | 122 | (S-RGB-M002)", | ||
120 | "sensorUnits": "mm" | 123 | "sensorUnits": "mm" | ||
121 | } | 124 | } | ||
122 | ], | 125 | ], | ||
123 | "state": "active", | 126 | "state": "active", | ||
124 | "tags": [], | 127 | "tags": [], | ||
125 | "title": "DECOMMISSIONED - St Laurent Li Taan Aen Staansyoon | 128 | "title": "DECOMMISSIONED - St Laurent Li Taan Aen Staansyoon | ||
126 | Sensors", | 129 | Sensors", | ||
127 | "titleType": "AlternativeTitle", | 130 | "titleType": "AlternativeTitle", | ||
128 | "type": "instrument_details", | 131 | "type": "instrument_details", | ||
129 | "url": null, | 132 | "url": null, | ||
130 | "valueURI": "SDN:P19::PLSR0226", | 133 | "valueURI": "SDN:P19::PLSR0226", | ||
131 | "version": null | 134 | "version": null | ||
132 | } | 135 | } |