You're currently viewing an old version of this dataset. To see the current version, click here.

This research output has no data

Related Collections and Datasets

Metadata

Field Value
Standardized Instrument Name METEOROLOGICAL STATIONS
Scheme URI http://vocab.nerc.ac.uk/collection/P19/current/PLSR0226/
Term URI SDN:P19::PLSR0226
Instrument DOI
Instrument Unique ID 30023406813390
ID Type Serial Number
Model No. H22-E14, SOH118303
Instrument Type Baseline
Description

Made up of multiple components listed below. Serial number is Iridium Weather station IMEI

Equipment cost: $9,904.50 + Iridium satellite Premium Plan: $1,350

Sensor details found in attachment - Instrument Details - HOBO MMF Weather Station 1

Manufacturer Hoskin Scientific Limited
Manufacturer type Organizational
Notes

HOBO brand field gear that includes various sensors attached to tripod outfitted with solar panel and battery located in housing box.

This meteorological station is located in St. Laurent and is owned by the Manitoba Métis Federation (MMF).

Calibration certificates stored in Lab Collector. They can be provided upon request.

Field Value
Sensor Details
Sensor Details 1
Instrument Sensor Name
Temperature and Relative Humidity
Instrument Sensor Serial No.
21048243
Sensor Range
Temperature: -40°C to 75°C (-40°F to 167°F); RH: 0-100% RH at -40° to 75°C (-40° to 167°F); exposure to conditions below -20°C (-4°F) or above 95% RH may temporarily increase the maximum RH sensor error by an additional 1%
Sensor Sensitivity
Temperature: ±0.21°C from 0° to 50°C (±0.38°F from 32° to 122°F); RH: ±2.5% from 10% to 90% RH typical to a maximum of ±3.5% including hysteresis at 25°C (77°F); below 10% and above 90% ±5% typical
Sensor Units
°C and %
Last Calibration Date
Sensor Details 2
Instrument Sensor Name
Photosynthetically Active Radiation (PAR)
Instrument Sensor Serial No.
21040570
Sensor Range
0 to 2500 μmol/m2/sec, wavelengths 400 to 700 nm
Sensor Sensitivity
±5 μmol/m2/sec or ± 5%, whichever is greater in sunlight; additional temperature induced error ±0.75 μmol/m2/sec/°C from 25°C (0.42 μmol/m2/sec/°F from 77°F)
Sensor Units
μmol/m2/sec
Last Calibration Date
Sensor Details 3
Instrument Sensor Name
Barometric Pressure
Instrument Sensor Serial No.
20812842
Sensor Range
Rated for -40C to +70C, must be used inside logger case, w/ 10 cm cable
Sensor Sensitivity
±3.0 mbar (0.088 in. Hg) over full pressure range at 25°C (77°F); maximum error of ±5.0 mbar (0.148 in. Hg) over -40° to 70°C (-40° to 158°F)
Sensor Units
mbar
Last Calibration Date
Sensor Details 4
Instrument Sensor Name
Wind sensor/monitor
Instrument Sensor Serial No.
21055171
Sensor Range
S-WCB-M003: 0 to 50 m/s (0 to 112 mph)
Sensor Sensitivity
0.20 m/s (0.46 mph) and 1.4 degrees
Sensor Units
m/s and degrees
Last Calibration Date
Sensor Details 5
Instrument Sensor Name
Rain Gauge
Instrument Sensor Serial No.
21050257
Sensor Range
0 to 12.7 cm (0 to 5 in.) per hour, maximum 4000 tips per logging interval
Sensor Sensitivity
0.01 in. (S-RGA-M002) or 0.2 mm (S-RGB-M002)
Sensor Units
mm
Last Calibration Date