<?xml version="1.0" encoding="utf-8"?>
<rdf:RDF
  xmlns:dcat="http://www.w3.org/ns/dcat#"
  xmlns:dc="http://purl.org/dc/elements/1.1/"
  xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#"
>
  <dc:description rdf:about="https://canwin-datahub.ad.umanitoba.ca/data/dataset/6bdadd9f-6c9b-469d-93b5-866745be6505">
    <dcat:Subject>WETLabs ECO Triplet sensor</dcat:Subject>
    <dcat:schemeURI>http://vocab.nerc.ac.uk/collection/L22/current/TOOL0674/2/</dcat:schemeURI>
    <dcat:valueURI>SDN:L22::TOOL0674</dcat:valueURI>
    <dcat:AlternateIdentifier>BBFL2WB-1436</dcat:AlternateIdentifier>
    <dcat:alternateIdentifierType>Serial Number</dcat:alternateIdentifierType>
    <dcat:modelNumber>1436</dcat:modelNumber>
    <dcat:instrumentType>Baseline</dcat:instrumentType>
    <dcat:Description>An ecotriplet is a three-optical-sensor,instrument that may carry any combination of single-wavelength fluorometers or scattering meters. The MBL ecotriplets are deployed on static moorings placed in the MBGL study lakes.&#13;
&#13;
The fluorometers can be configured (with typical sensitivities) for chlorophyll (470/695 nm, sensitivity 0.015-0.025 ug/l), FDOM (370/460 nm, sensitivity 0.184 ppb), phycocyanin (630/680 nm, 0.086 ppb), phycoerythrin (520/595 nm, sensitivity 0.086 ppb), The scattering meter can typically measure optical scattering at blue, green or red wavelengths (412, 470, 532, 650, 700 and 880 nm, sensitivity 0.002-0.003 m-1).</dcat:Description>
    <dcat:instrumentCreatorName>Wetlabs</dcat:instrumentCreatorName>
    <dcat:nameType>Organizational</dcat:nameType>
    <dcat:sensorDetails>
      <rdf:Description rdf:nodeID="Nacc5af766aca44b7b231eaf49fd2eb56">
        <dcat:instrumentSensorName>ECO Phycocyanin (PC) Fluorometer</dcat:instrumentSensorName>
        <dcat:instrumentSensorSerialNumber>BBFL2WB-1436</dcat:instrumentSensorSerialNumber>
        <dcat:sensorRange>0-175</dcat:sensorRange>
        <dcat:sensorSensitivity>0.086</dcat:sensorSensitivity>
        <dcat:sensorUnits>ppb</dcat:sensorUnits>
      </rdf:Description>
    </dcat:sensorDetails>
    <dcat:sensorDetails>
      <rdf:Description rdf:nodeID="Ne0eaee5c8a9a4e9caa1af2c5f366463f">
        <dcat:instrumentSensorName>ECO Chlorophyll (Chl) Flurometer</dcat:instrumentSensorName>
        <dcat:instrumentSensorSerialNumber>BBFL2WB-1436</dcat:instrumentSensorSerialNumber>
        <dcat:sensorRange>0-30; 0-50</dcat:sensorRange>
        <dcat:sensorSensitivity>0.015; 0.025</dcat:sensorSensitivity>
        <dcat:sensorUnits>ug/l</dcat:sensorUnits>
      </rdf:Description>
    </dcat:sensorDetails>
    <dcat:sensorDetails>
      <rdf:Description rdf:nodeID="N6407fe116f744fd8836ae69b6a4222b5">
        <dcat:instrumentSensorName>Scattering Meter</dcat:instrumentSensorName>
        <dcat:instrumentSensorSerialNumber>BBFL2WB-1436</dcat:instrumentSensorSerialNumber>
        <dcat:sensorRange>0-5; 0-3; 0-5</dcat:sensorRange>
        <dcat:sensorSensitivity>0.003; 0.002</dcat:sensorSensitivity>
        <dcat:sensorUnits>m-1</dcat:sensorUnits>
      </rdf:Description>
    </dcat:sensorDetails>
    <dcat:relation>
      <rdf:Description rdf:nodeID="Ncbee3bee6015464381077a9d4d9df81b">
        <dcat:entity_type>campaign</dcat:entity_type>
        <dcat:relation_type>related_to</dcat:relation_type>
        <dcat:title>MBGL Synoptic Survey 1 May-June 2016</dcat:title>
        <dcat:url>https://canwin-datahub.ad.umanitoba.ca/data/campaign/mbgl-ss1-may-june-2016</dcat:url>
      </rdf:Description>
    </dcat:relation>
    <dcat:relation>
      <rdf:Description rdf:nodeID="Ndd2fc79520234dd790c684d93eac7447">
        <dcat:entity_type>campaign</dcat:entity_type>
        <dcat:relation_type>related_to</dcat:relation_type>
        <dcat:title>MBGL Synoptic Survey 2 July 27 - August 20, 2016</dcat:title>
        <dcat:url>https://canwin-datahub.ad.umanitoba.ca/data/campaign/mbgl-ss2-july-august-2016</dcat:url>
      </rdf:Description>
    </dcat:relation>
  </dc:description>
</rdf:RDF>